Chapter 1 MIO and AI Devices
©
National Instruments Corporation 1-3 DAQ Hardware Overview Guide
Note Terms such as ADC resolution and analog trigger are defined in the Glossary.
E Series Data Acquisition
The E Series devices can perform single-channel data acquisitions and
multiple-channel scanned data acquisitions. For single-channel data
acquisition, select a single analog input channel and gain setting. The
device performs a single A/D conversion on that channel every sample
interval.
For multiple-channel scanned data acquisition, the device scans a set of
analog input channels, each with its own gain setting. In this method, a scan
sequence indicates which analog channels to scan and the gain settings for
each channel. The length of this scan sequence can be 1 to 512 channel/gain
pairs. For the PCI-6110E and the PCI-6111E each channel can appear only
once in the scan sequence.
During scanning, the analog input circuitry performs an A/D conversion on
the next entry in the scan sequence. The device performs an A/D conversion
once every sample interval. For maximum performance, this operation is
pipelined so that the device switches to the next channel while the current
A/D conversion is performed. The device waits for a specified scan interval
before scanning the channels again. The channels are scanned repeatedly at
the beginning of each scan interval until the required number of samples
has been acquired. For example, you can scan a sequence of four channels
once every 10 s. The device could sample the channels at the beginning of
the 10 s interval, within 20 µs, with a 5 µs sample interval between
channels. If you set the scan interval to 0, the scan sequence starts over
again immediately at the end of each scan sequence without waiting for a
scan interval. The 0 scan interval setting causes the device to scan the
channels repeatedly as fast as possible.
Note The 611X devices sample all channels simultaneously. The scan interval controls the
sampling rate, therefore the scan interval of zero is not allowed.
DAQCard-6023E 16 12 0.5, 1, 10, 100 ±5 2048 no
DAQCard-6024E 16 12 0.5, 1, 10, 100 ±5 2048 no
DAQCard-6062E 16 12 0.5, 1, 2, 5, 10,
20, 50, 100
±5 8192 yes
Table 1-1. MIO and AI Multifunction I/O Device Analog Input Characteristics (Continued)
Device
Number
of
Channels
ADC
Resolution
(Bits)
Gains Range (V)
Input
FIFO
(Words)
Hardware
Analog
Trigger
Seitenansicht 19